**的操控面板冷却体系:Patented control panel cooling system: 所述冷却体系(可选)有助于遣散热量,由于长期运转,致使电子部件上的过热。在露天装置,有助于下降冷却电扇操控面板里边建立起来的尘土粒子。The cooling system (optional) helps to dissipate heat, resulting in overheating of electronic components over long periods of time. In the open air installation, it is helpful to reduce the dust particles built up in the cooling fan control panel. 直流高压电源:DC high voltage power supply: 高直流电压电源供应器有个微型处理器的操控,提供了坚实的状况和自我调节坚持峰值功率的电源供应器。一切的电其输出满意了电器*CE usage的请求。The high DC voltage power supply has a micro processor control, which provides a solid state and self regulation to maintain the peak efficiency of the power supply. All of its output meets the requirements of electrical safety usage CE. 楼宇办理体系(BMS)衔接:Building management system (BMS) connection: 静电除尘器有才能与楼宇办理体系衔接,经过一个内置的BMS接口(可选)项目预备或毛病干接点衔接在每个操控面板。BMS体系将具有短路维护,**载防止操控以及主动发动或手动功用。The electrostatic precipitator has the ability to connect with the building management system, through a built-in BMS interface (optional) project preparation or the failure of the dry contact is connected to each control panel. BMS system will have short circuit protection, overload prevention and control, as well as automatic start or manual function. 装置注意事项Installation notes 1. 净化体系内通风量应在净化器额定处理风量内;1the amount of ventilation in the purification system should be within the rated air flow rate of the purifier; 2. 净化器装置应确保水平,不然,净化器搜集的油会被风机吸出,或放油时不能将净化器内的油放尽; installation should ensure that the level, otherwise, the oil purifier collected by wind suction, or put the oil can not be put in the oil purifier; 3. 管道内风速应规划在8-10m/s; wind speed pipe should be designed in 8-10m/s 4. 弯头中线半径≥1.5D(若不满意此条件,则变径管风阻会成倍增大) elbow radius is larger than 1.5D midline (if not meet this condition, it will increase the drag reducing pipe) 5. 变径管(小变大)斜边与轴线夹角≤70(若不满意此条件,应考虑合理装置导流板。不然,净化器净化功率将大幅度下降而不能达到国家排放规范) tube (small and large) bevel angles with the axis is less than or equal to 70 (if you do not meet this condition, should consider the reasonable installation guide plate. Otherwise, the purification efficiency of the purifier will be greatly reduced and can not meet the national emission standards. 6. 变径管(大变小)你斜边与轴线夹角≤150(若不满意此条件,应考虑合理装置导流板。不然,净化器不能表现器效能)。如图所示;7 tube (big or small) your bevel angles with the axis is less than or equal to 150 (if you do not meet this condition, should consider the reasonable installation guide plate. Otherwise, the purifier can not play the effectiveness of the device. As shown in figure; 7. 净化器进风口之前应有一段≥2.5D的直管(若不满意此条件,应考虑合理装置气流均布板和导流板。不然,净化器不能表现器效能 );Before the 8 air purifier should be a straight over 2.5D (if this condition is not met, should consider the reasonable layout and installation flow guide plate. Otherwise, the purifier can not play the effectiveness of the device; 8. 风机应装置减振器;fan should be installed vibration damper; 9. 风机进出风口应装置软衔接; wind turbine inlet and outlet should be installed soft connection; 10. 净化器有必要牢靠接地(净化器有3根出线,红线和绿线接220V/AC,黄绿线接地)purifier must be reliable grounding (purifier has 3 stages, red and green 220V/AC, green line) 11. 风向问题:设备出厂均设定为左进风(面临净化器电气箱的门),风向活动邮左进风,反之则为右进风)。若现场需用右进风,电场旋转180°,将绷簧接头由下方移至上方,再将高压线对换则完成了由左进风调整为右进风之进程。wind problem: equipment factory was set up at the left Jinfeng (face purifier electric box door), wind flow post left Jinfeng, whereas right into the wind). If the site use right into the wind, the electric field will rotate 180 degrees, from below to above the spring joint, then on the high voltage line is completed by adjusting inlet for Jinfeng left right. 12. 为确保设备的净化功率,设备作业在负风压状况,即风机有必要设在设备后边。 in order to ensure the efficiency of the equipment, the equipment works in a negative pressure state, that is, the wind turbine must be located in the back of the equipment. 13. 室外装置时,应加装防雨、遮阳的遮阳蓬,以免影响设备的正常使用寿命以及添加不必要的维护费用。 outdoor installation, should be equipped with sunshade rainproof and sunshade, so as not to affect the normal service life of equipment and increase unnecessary maintenance costs.